NextRaiseNextRaiseFind jobs
Sign inSign up free
Jobs / QA Engineer in United States of America
12 days ago
Apply with autofill
Apply with autofill
Sapsol-technologies-inc-7·12 days ago
12 days ago

EMI/EMC Test Engineer

Glasgow, United States of AmericaMid · 3-7 yearsQA Engineer

Sign up free to see how well your resume matches this role.

Boost your chances at sapsol-technologies-inc-7

How you compare FREE

?
Your scoreYour score: not yet known
→
47
Top 10%Top 10%: 47 out of 100

Top 10% of NextRaise users matched against QA Engineer roles in United States.

Must-have skills for this role

  • emi/emc testing
  • iec 60601-1-2
  • iec 61000-4
  • emi receivers

PDF or DOCX · no account needed

Apply faster with autofill FREEsapsol-technologies-inc-7 uses Workable - autofill it instead of retyping.careers.example.com/applyAutofillingFull namePriya SharmaEmailpriya.sharma@example.comPhone+49 30 1234567LocationBerlGet the extension

What you'll do

  • Plan, execute, and analyze EMC pre-compliance and full-compliance testing per IEC 60601-1-2 (radiated/conducted emissions, radiated/conducted immunity, ESD, EFT/burst, surge, magnetic field immunity, dips & interruptions)
  • Apply collateral/particular standards as applicable (e.g., IEC 60601-1-11 for home healthcare environments, IEC 60601-2-XX device-specific standards)
  • Support wireless coexistence testing for connected medical devices (BLE, Wi-Fi) per FDA guidance on RF wireless technology
  • Conduct EMC design reviews at schematic, PCB layout, cable/harness, and enclosure stages — especially around patient-connected circuits and isolation boundaries
  • Debug EMI/EMC failures using spectrum analyzers, EMI receivers, near-field probes, ESD simulators, and surge/EFT generators
  • Coordinate with accredited third-party test labs (e.g., UL, TÜV, Intertek) for formal IEC 60601-1-2 certification testing
  • Author and maintain EMC test plans, protocols, and reports suitable for FDA 510(k)/PMA submissions and CE technical files (MDR)
  • Link EMC test results to risk management file (ISO 14971) — document hazards, mitigations, and residual risk related to electromagnetic disturbances
  • Recommend and validate design mitigations (shielding, filtering, grounding, isolation) without compromising patient safety or essential performance
  • Support root-cause investigation for field complaints or CAPAs related to EMC issues
  • Maintain traceability between EMC test evidence and Design History File (DHF) per IEC 62304/design control requirements
  • Track evolving global regulatory requirements (FDA, EU MDR, Health Canada, etc.) affecting EMC for medical devices

What they're looking for

  • Bachelor's degree in Electrical/Biomedical Engineering or related field
  • 3–7 years of EMI/EMC experience, with at least 2+ years specific to medical devices
  • Working knowledge of IEC 60601-1-2 and its test methods (IEC 61000-4 series as applied to medical devices)
  • Understanding of "essential performance" and "basic safety" concepts as they relate to EMC pass/fail criteria
  • Experience with EMC test equipment: EMI receivers, spectrum analyzers, ESD guns, surge/EFT/burst generators, near-field probes
  • Ability to read schematics/PCB layouts, particularly isolation barriers and patient-applied parts
  • Strong technical writing skills for regulatory-grade documentation

Summarised by NextRaise from the employer’s description, which follows in full below.

Full description from employer

 

No of Position:01

Job Summary

We are seeking an EMI/EMC Test Engineer to own electromagnetic compatibility and electromagnetic interference testing for our medical device portfolio, ensuring compliance with IEC 60601-1-2 and supporting FDA/international regulatory submissions. The role works closely with R&D, systems engineering, and regulatory affairs to identify and mitigate EMC risks throughout the design lifecycle, particularly for devices operating in clinical and home-use environments.

Required Qualifications

  • Bachelor's degree in Electrical/Biomedical Engineering or related field
  • 3–7 years of EMI/EMC experience, with at least 2+ years specific to medical devices
  • Working knowledge of IEC 60601-1-2 and its test methods (IEC 61000-4 series as applied to medical devices)
  • Understanding of "essential performance" and "basic safety" concepts as they relate to EMC pass/fail criteria
  • Experience with EMC test equipment: EMI receivers, spectrum analyzers, ESD guns, surge/EFT/burst generators, near-field probes
  • Ability to read schematics/PCB layouts, particularly isolation barriers and patient-applied parts
  • Strong technical writing skills for regulatory-grade documentation

Key Responsibilities

  • Plan, execute, and analyze EMC pre-compliance and full-compliance testing per IEC 60601-1-2 (radiated/conducted emissions, radiated/conducted immunity, ESD, EFT/burst, surge, magnetic field immunity, dips & interruptions)
  • Apply collateral/particular standards as applicable (e.g., IEC 60601-1-11 for home healthcare environments, IEC 60601-2-XX device-specific standards)
  • Support wireless coexistence testing for connected medical devices (BLE, Wi-Fi) per FDA guidance on RF wireless technology
  • Conduct EMC design reviews at schematic, PCB layout, cable/harness, and enclosure stages — especially around patient-connected circuits and isolation boundaries
  • Debug EMI/EMC failures using spectrum analyzers, EMI receivers, near-field probes, ESD simulators, and surge/EFT generators
  • Coordinate with accredited third-party test labs (e.g., UL, TÜV, Intertek) for formal IEC 60601-1-2 certification testing
  • Author and maintain EMC test plans, protocols, and reports suitable for FDA 510(k)/PMA submissions and CE technical files (MDR)
  • Link EMC test results to risk management file (ISO 14971) — document hazards, mitigations, and residual risk related to electromagnetic disturbances
  • Recommend and validate design mitigations (shielding, filtering, grounding, isolation) without compromising patient safety or essential performance
  • Support root-cause investigation for field complaints or CAPAs related to EMC issues
  • Maintain traceability between EMC test evidence and Design History File (DHF) per IEC 62304/design control requirements
  • Track evolving global regulatory requirements (FDA, EU MDR, Health Canada, etc.) affecting EMC for medical devices

 

 

Company

Sapsol-technologies-inc-7
Glasgow, United States of America

Company facts come from this company's own listings. We only show what the postings themselves carry.

Sourced from Sapsol Technologies Inc 7's careers site·first seen 9 Sept 2026·last verified 9 Sept 2026·How we source jobs

Similar jobs

  • Sr Supervisor Quality Assurance at globalhrWILSON, United States of America–match not yet calculated
  • Systems Test Engineer II at globalhrPLANO, United States of America–match not yet calculated
  • Senior Systems Test Engineer at globalhrPLANO, United States of America–match not yet calculated
  • Quality Assurance (QA) Project Engineer at moogBuffalo, United States of America–match not yet calculated
  • Tech Lead - Testing & Quality Assurance S 4C at Genpact3409, United States of America–match not yet calculated

Browse more jobs

  • QA Engineer jobs in United States
  • QA Manager jobs in United States
  • Automation Test Engineer jobs in United States
  • Performance Test Engineer jobs in United States
  • QA Engineer jobs in India
  • QA Engineer jobs in United Kingdom